Ultrasonic Distance Sensor with UART & PWM Output – Specimen Track

Ultrasonic sensor with a 45° beam angle, 25-450 cm range, UART/PWM output, 3.3-5V supply, and high accuracy. Ideal for precise distance measurements

SKU: STRLDS-110 Category:

Overview

Specimen Track ultrasonic LiDAR parking sensor adopts a high-performance processor and high-quality components. Sensors are stable and reliable with long life spam. The module design with waterproof ultrasonic transduce suitable for different working environments. Built-in high-precision distance sensing algorithm and power consumption management program, high measuring accuracy and low power consumption.

 

Features

  • Design with intelligent signal processing circuit, small dead band
  • Large measuring range
  • Build in high precision distance sensing algorithm
  • Minimum error <0.2 in
  • Build in authentic target identification algorithm
  • Controllable measuring angle, high sensitivity and anti-jamming
  • Specific measuring mode setting available for human or flat objects
  • High level PWM output, UART output, Switch output optional
  • Temperature compensation at 5 ℉ to 140 ℉ (-15 ℃ to 60 ℃)
  • Lower power consumption design, standby current <5 uA
  • Operating current 15 mA (3.3 V supply voltage)
  • Anti-static electricity design in accordance with IEC 61000-4-2 standard
  • Intelligent algorithm circuit, SMT, more stable
  • 01 ft probe extended cable, support different applications
  • IP 67 protection integrated probe
  • Measuring range and dead band
  • Transceiver split waterproof probe, silicone protection and shockproof
  • Single row pitch 0.1 in 4P

 

Technical Specifications

Dead Band9.84 in (25 cm)
Measuring range of Flat objects9.84 in to 177.7 in (25 cm to 450 cm)
Beam Angle≈45°
Response time300 ms to 500 ms, 15 ms to 65 ms, 300 ms to 500 ms, 8 ms to 15 ms
MTTF26000 Hrs
Supply Voltage3.3 V to 5.0 V (DC)
Residual ripple<50 mA
Power consumption≤20 mA
Connection typeUART automatic, UART control, PWM,Switch
Output signalTTL signal, Pulse width signal
Output current<9 mA
Measurement accuracy±1 and S x 0.3% cm,±1 and S x 0.5% cm
Process connectionSingle row pitch 0.1 in (2.54 mm) 4P
Housing materialABS
Ambient operating temperature5 ℉ to 140 ℉ (-15 ℃ to 60 °C)
Ambient temperature storage-13 ℉ to 176 ℉ (-25 ℃ to 80 °C)