Features
- Max battery life 15 years
- Exceptional IP 68 proof
- Detecting pipe leaks
- Install in any position
Technical Specifications
| Parameter | Description |
| Q4 | 3.125 m3 per h |
| Q3 | 2.5 m3 per h |
| Q2 | 0.01 m3 per h |
| Q1 | 0.00625 m3 per h |
| Start Flow Rate | 0.002 m3 per h |
| Dynamic Range | R400 |
| Medium Temperature | Cold water |
| Frequency | LoRa or LoRaWAN 868MHz, 902MHz, 915MHz, 920MHz |
| Counter Instructions | Digital |
| Principle | Speed of water meter |
| Work Environment | Dry water meter |
| Measured Medium | Water |
| Metrological Class | Class 2 |
| Battery | 3.6 V, Li-battery ER 26500 (default) or ER 34615 |
| Battery Life | ≥ 10 years |
| Consumption | < 0.2 mW |
| Pressure Loss | DN 15-DN 25: Ap 40; DN 32-DN 40: Aр 63 |
| Emc | E1 |
| Environmental Classification | Class b |
| Protection Class | IP 68 |
| Accuracy | ± 5 % in range Q1 ≤ Q < Q2 ± 2 % in range Q2 ≤ Q < Q4 |
| Map | PN 16 |
| Material | Brass 59-1 |
| Installation Sensitivity | U 0 or D 0 |
| Climatic and Mechanical Environmental Grades | M1 |
| Display | LCD 9 digit + prompt |
| Display Range | Total flow: 0 m² to 99999.9999 m² |
| Communication | Optical port, M-bus, RS-485, pulse output, LoRa, LoRaWAN, NB-IoT |
| Medium Temperature | T 50 or T 90 |
| Storage Temperature | 77 °F to 131 °F (-25 °C to 55 °C) |
| Dimension | 6.50 in x 3.35 in x 3.35 in (165 mm x 85 mm x 85 mm) |






Reviews