| Input Power Supply |
AC 220 V, 50 Hz |
| Charging Adapter |
DC 12 V, DC 16.8 V |
| Fault Testing Unit – Display |
12.1-inch industrial grade LCD screen |
| Storage Space |
4G electronic disk |
| Testing Methods |
Low voltage pulse method, lightning current method, multiple pulse method |
| Operation Method |
Knob mouse operation |
| Testing Distance |
Not less than 31 mi (50 km) |
| Minimum Testing Distance |
16.4 ft (5 m) |
| Precision Positioning Error |
± 0.2 m |
| Testing Error |
System error less than ± 1% |
| Pulse Generator Impulse Voltage |
≤ 40k V |
| Resolution |
v/f m |
| Sampling Frequency |
200 MHz, 100 MHz, 50 MHz, 25 MHz, 12.5 MHz, 6.25 MHz |
| Pulse Width |
100ns, 200ns, 500ns, 1 μ s. 2 μ s. 5 μ S (software automatic matching) |
| Power Supply – AC |
AC 220 V ± 10%, ≤ 15 W |
| Power Supply – DC |
DC 12 V (7AH), ≤ 20 W |
| Standby Time |
Continuous use for about 6 hours |
| High-Frequency Power Supply Output Voltage |
≤ 32k V (negative pressure) |
| Output Methods |
Pulse output, DC output |
| Output Voltage |
Negative pressure, ≤ 32k V |
| Working Mode |
Single pulse, continuous pulse, DC output |
| Built in Capacitor |
4 uF / 32k V |
| Discharge Energy |
≤ 2048J |
| Path Testing Detection Distance |
3.1 mi (5 km) |
| Path Detection Depth |
9.84 ft (3 m) |
| Routing Error |
± 2 in (± 5 cm) |
| Output Frequency |
9.6k Hz |
| Output Power |
5 W |
| Insulation Resistance Output Voltage |
500 V, 1000 V, 2500 V, 5000 V |
| Ultra Quiet Sensor Range |
100 Hz to 1500 Hz |
| Low Pass Filtering |
100 Hz to 400 Hz |
| Band Pass Filtering |
150 Hz to 600 Hz |
| High Pass Filtering |
200 Hz to 1500 Hz |
| LCD Display (Fault Detection Unit) |
High brightness true color, 320 x 240 pixels suitable for outdoor use |
| Trolley Dimensions |
20.87 x 16.93 x 37.8 in (530 x 430 x 960 mm) |
| Trolley Weight |
110.23 lbs (50 kg) |